Everything IOT

Default

LoRaWAN Multi-Flow Smart Water Mete...

Multi-flow dry valve-controlled water me...

Related Product Cover
Default

T0005250-J, LORA GATEWAY MODULE, KO...

The KONA Macro IoT Gateway is an ideal s...

Related Product Cover
Default

LoRaWAN Single-phase Electric Meter

single-phase fee-controlled intelligent...

Related Product Cover
Default

Wireless O3 Sensor (DC-powered)

The R718PA3 is a wireless communication ...

Related Product Cover
Review rating Review rating Review rating Review rating Review rating 190 views

LoRaWAN Domestic Membrane Gas Meter with Steel Casing

The movement is integrated with mold and injection, and the structure is simple; The whole movement has only 27 kinds of 45 parts, reduce the number of parts, reduce accumulated errors to ensure the accuracy and reliability of measurement;The rotary distribution structure is adopted, which runs smoothly, overcomes the defects of reciprocating distribution structure and enhances the measurement reliability;The rotation is stable and never leaks, thus ensuring the safety performance of the product; The rotation of the movement transmission mechanism is transmitted to the counter outside the shell through magnetic force, ensuring accurate measurement, stable performance and good consistency of repeated detection; The internal control indication error index is ± 1%, which can ensure that the detection in different regions can be qualified;The surface of the shell is treated with plastic spraying, which has bright color, beautiful appearance and good corrosion resistance. It is designed with a variety of structures and devices to prevent external interference and damage.

Total price:

$0.00

Select quantity
High measurement accuracy. The movement redesigns the rotating volume, and the difference between the diaphragm volume and the standard volume is less than 10%, so the change of the rotating volume will be very small within the size error range of each part, improve the accuracy of measurement;
High stability and good consistency of repeat detection. Unique diaphragm limit and forced diaphragm turnover device is adopt.The limit of each movement of the diaphragm is at the same position, so that each movement of the diaphragm is filled with the same amount of gas, even after multiple movements and testing, the error of multiple detection is greatly reduced, and the stability of the meter and the consistency of repeated detection are improved;
Good durability. The low-temperature diaphragm is adopted, and has very good softness, and will not deform after multiple operations, so that the rotation volume will not change too much, and the durability of the meter is greatly improved.